Function |
May be a cytokine that affects the growth, movement, or activation state of cells that participate in immune and inflammatory response. |
Protein Name |
C-X-C Motif Chemokine 9Gamma-Interferon-Induced MonokineMonokine Induced By Interferon-GammaMigMumigProtein M119Small-Inducible Cytokine B9 |
Database Links |
Reactome: R-MMU-380108Reactome: -MMU-418594 |
Cellular Localisation |
Secreted |
Alternative Antibody Names |
Anti-C-X-C Motif Chemokine 9 antibodyAnti-Gamma-Interferon-Induced Monokine antibodyAnti-Monokine Induced By Interferon-Gamma antibodyAnti-Mig antibodyAnti-Mumig antibodyAnti-Protein M119 antibodyAnti-Small-Inducible Cytokine B9 antibodyAnti-Cxcl9 antibodyAnti-Mig antibodyAnti-Scyb9 antibody |
Specificity |
This kit recognizes Mouse MIγ/CXCL9 in samples. No significant cross-reactivity or interference between Mouse MIγ/CXCL9 and analogues was observed. |
Reproducibility |
Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item |
Specifications |
Storage |
Micro ELISA Plate (Dismountable) |
96T: 8 wells ×12 strips strips |
-20℃, 6 months |
Reference Standard |
96T: 2 vials 48T: 1 vial |
-20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) |
96T: 1 vial, 120 μL 60 μL |
-20℃, 6 months |
Concentrated HRP Conjugate (100×) |
96T: 1 vial, 120 μL 60 μL |
-20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent |
1 vial, 20 mL |
2-8°C, 6 months |
Biotinylated Detection Ab Diluent |
1 vial, 14 mL |
2-8°C, 6 months |
HRP Conjugate Diluent |
1 vial, 14 mL |
2-8°C, 6 months |
Concentrated Wash Buffer (25×) |
1 vial, 30 mL |
2-8°C, 6 months |
Substrate Reagent |
1 vial, 10 mL |
2-8℃ (Protect from light) |
Stop Solution |
1 vial, 10 mL |
2-8°C |
Plate Sealer |
5 pieces |
|
Manual |
1 copy |
|
Certificate of Analysis |
1 copy |
|
Sample Type |
Range (%) |
Average Recovery (%) |
Serum(n=8) |
91-102 |
96 |
EDTA plasma (n=8) |
90-105 |
97 |
Cell culture media (n=8) |
92-110 |
100 |
|
Intra-assay Precision |
Intra-assay Precision |
Intra-assay Precision |
Inter-assay Precision |
Inter-assay Precision |
Inter-assay Precision |
Sample |
1.00 |
2.00 |
3.00 |
1.00 |
2.00 |
3.00 |
n |
20.00 |
20.00 |
20.00 |
20.00 |
20.00 |
20.00 |
Mean (pg/mL) |
156.80 |
445.80 |
1497.30 |
154.10 |
484.80 |
1422.10 |
Standard deviation |
10.70 |
23.60 |
46.40 |
9.70 |
22.80 |
58.30 |
CV (%) |
6.82 |
5.29 |
3.10 |
6.29 |
4.70 |
4.10 |