RSeQC python runtime errors for tin.py

1

Hello,

I am attempting to use the tin.py script in the RSeQC package, on BAM files generated by STAR aligner.

When running tin.py, I end up with the following error:

/python-2.7.15/lib/python2.7/site-packages/numpy/core/fromnumeric.py:2957: RuntimeWarning: Mean of empty slice.
  out=out, **kwargs)

/python-2.7.15/lib/python2.7/site-packages/numpy/core/_methods.py:80: RuntimeWarning: invalid value encountered in double_scalars
  ret = ret.dtype.type(ret / rcount)

/python-2.7.15/lib/python2.7/site-packages/numpy/core/_methods.py:135: RuntimeWarning: Degrees of freedom <= 0 for slice
  keepdims=keepdims)

/python-2.7.15/lib/python2.7/site-packages/numpy/core/_methods.py:105: RuntimeWarning: invalid value encountered in true_divide
  arrmean, rcount, out=arrmean, casting='unsafe', subok=False)

/python-2.7.15/lib/python2.7/site-packages/numpy/core/_methods.py:127: RuntimeWarning: invalid value encountered in double_scalars
  ret = ret.dtype.type(ret / rcount)

@ 2018-06-09 12:14:41: Processing CmusAligned.sortedByCoord.out.bam

I don't know where to start fixing this/don't know where the problem comes from, so any guidance would be much appreciated!

freuv


RNA-Seq


sequencing


software error

• 1.5k views

updated 2 hours ago by

&utrif;

10

written 3.1 years ago by

&utrif;

20

Old post, but I just had the same issue. The warnings are numpy warnings due to division by zero. In my case, the transcripts were not getting any coverage (see the .xls output) because the chromosomes in the .bed reference and the bam file were different. In the bam file, the chromosomes were called chr1, chr2, ... and in the genome which was used during alignment, the chromosomes were simply numbered 1, 2, ...

I fixed this by removing the 'chr' prefix from the chromosomes in the .bed file I used as reference:

awk 'BEGIN{FS=OFS="t"} {gsub(/chr/, "", $1)} 1' reference.bed > no_chr_prefix_reference.bed